The Fuze is used for 155 mm/ 105 mm Artillery Ammunition. The design of Time Fuze aims to provide greater accuracy & flexibility of operation. It is programmable for any delay time range of 3.0-199 sec, with increments of 0.1 second. It is also used with carrier shells (Smoke, Illuminating, Cargo).
Product Specification
Basic information
Action-Impact (SQ) & Time delay
Arming-Mechanical
Fuze arming Time-Fuze arms after 500 milliseconds from launch time.
Muzzle Safety Distance-Min.100 meters from the muzzle end
Mode Setting-Inductive (with the help of fuze setter) | Time function from 3.0 to 199 seconds with increments of 0.1 seconds. | Point Detonationg Super Quick.
Velocity and Pressure-The electronic fuze is safe for use of Muzzle | velocity range from 180 to 1000m/s. | The fuze is able to withstand chamber | pressure up to 397±8 MPa for 155 mm & | pressure up to 391±8 MPa for 105 mm.
Storage Temperature Range--30° to 55°
Firing Temperature Range--30° to 55°
Self-Life-15 years
Safety Type-Electronic & Mechanical
Acceleration-1500 to 30000 g
Rotation-2700 to 30000 rpm
Weight of fuze-835±25 grams.
International standard-MIL-STD 1316, MIL-STD 331, MIL-STD 4187